AMBE-3000F™ Vocoder Chip Users Manual
Version 3.4, April, 2014
Dat
a and Configuration Packets
If m
ode is 0 then parity fields will be disabled for all output packets beginning with the response to this packet. The AMBE-
3000F™ Vocoder Chip will not require a valid parity byte for future received packets.
If mode is 1 then parity fields will be enabled for all output packets beginning with the response to this packet. The AMBE-
3000F™ Vocoder Chip will reject all future received packets that do not have a valid parity field.
All other values for mode are reserved and should not be used.
PKT_PARITYMODE Response field (2 bytes) this field indicates that the PKT_PARITYMODE field in the corresponding
control packet was received without error.
PKT_PARITYMODE Response Field - Format
Field Identifier Response Field Data
1 Byte 1 Byte
0x3F
0x00
(anything different indicates error)
Table 81 PKT_PARITYMODE Response Field
PKT_WRITEI2C field (n bytes plus 2) this field writes to an I
2
C device such as a codec.
PKT_WRITEI2C Field - Format
Control Fields Data
Field Identifier
Length LenBytes
1 Byte 1 Byte
0x44 n Codec Data
Table 82 PKT_ WRITEI2C Field Format
PKT_WRITEI2C Response field (2 byte) this field indicates that the PKT_WRITEI2C field in the corresponding control data
was received without error.
PKT_WRITEI2C Response Field - Format
Field Identifier Response Field Data
1 Byte 1 Byte
0x44
0x00
(anything different indicates error)
Table 83 PKT_WRITEI2C Response Field
PKT_CLRCODECRESET field (1 byte total) this field sets the codec reset signal to low.
PKT_CLRCODECRESET Field - Format
Field Identifier Control Field Data
1 Byte 0 Byte
0x46 No Data Needed
Table 84 PKT_CLRCODECRESET Field Format
PKT_CLRCODECRESET Response field (2 bytes) this field indicates that the PKT_CLRCODECRESET packet was
received without error.
PKT_CLRCODECRESET Response Field - Format
Field Identifier Response Field Data
1 Byte 1 Byte
(Subject to Change) Page 75